CarboProbe HT

Based on the ZrO2 C-700 Electrolyte, the CarboProbe HT probe measures oxygen concentration and can handle temperatures up to 1700°C (3100°F). All parts exposed to high temperatures are ceramic or platinum. This probe has a robust construction with a 15 mm (~1/2") diameter ceramic tube that protects the internal measurement device.

This CarboProbe HT cannot be used for the measurement of oxygen in carburizing mixtures.

Documentation

Download the pdf Instruction Manual

Download the pdf Brochure

Download the pdf Technical Sheet

Ordering Information

CarboProbe HT, 300 mm (11.8"), R, 3/4" connection Buy Online
CarboProbe HT, 400 mm (15.7"), R, 3/4" connection Buy Online
CarboProbe HT, 500 mm (19.7"), R, 3/4" connection Buy Online
CarboProbe HT, 600 mm (23.6"), R, 3/4" connection Buy Online
CarboProbe HT, 700 mm (27.5"), R, 3/4" connection Buy Online
CarboProbe HT, 800 mm (31.5"), R, 3/4" connection Buy Online
CarboProbe HT, 900 mm (35.4"), R, 3/4" connection Buy Online
CarboProbe HT, 1000 mm (39.4"), R, 3/4" connection Buy Online
CarboProbe HT, 1100 mm (43.3"), R, 3/4" connection Buy Online
CarboProbe HT, 300 mm (11.8"), S, 3/4" connection Buy Online
CarboProbe HT, 400 mm (15.7"), S, 3/4" connection Buy Online
CarboProbe HT, 500 mm (19.7"), S, 3/4" connection Buy Online
CarboProbe HT, 600 mm (23.6"), S, 3/4" connection Buy Online
CarboProbe HT, 700 mm (27.5"), S, 3/4" connection Buy Online
CarboProbe HT, 800 mm (31.5"), S, 3/4" connection Buy Online
CarboProbe HT, 900 mm (35.4"), S, 3/4" connection Buy Online
CarboProbe HT, 1000 mm (39.4"), S, 3/4" connection Buy Online
CarboProbe HT, 1100 mm (43.3"), S, 3/4" connection Buy Online

Do you have a special request? Don’t hesitate to ask!

Maintenance

There are no maintenance parts required inside the sensor, if the platinum external connector is damaged it can be repaired without loss of signal quality.

Technical Characteristics

Output 0 to 1200 mv
Redout impedance This probe should be used with controlling, recording, and indicating instruments having input impedance of 8 megaohms or higher.
Accuracy ±2 mV in normal operating range
Response time Less than 1 second
Thermocouple R, S
Operating temperature From 600°C (1100°F) to 1700°C (3100°F)
Mechanical shock Resists mild mechanical shock. Handle carefully.
Available lengths 300mm (11.8"), 400mm (15.7"), 500mm (19.7"), 600mm (23.6"), 700mm (27.5"), 800mm (31.5"), 900mm (35.4"), 1000mm (39.4"), 1100mm (43.3")
Reference air Uncontaminated dry air at maximum rate of 1 l/h
External diameter 15 mm (~1/2")