Econox USA Logo
330.678.3889
info@econox.us

CarboProbe DS

The CarboProbe DS is a laboratory oxygen probe, suitable for measurement of oxygen concentration over the range from pure oxygen down to 10-24 atmospheres at temperatures from 700°C to 1700°C. It consists of a ZRO2 oxygen sensor with an internal thermocouple. All wiring and electrodes are platinum, for the best possible corrosion resistance.

Documentation

Download the pdf Instruction Manual

Download the pdf Brochure

Download the pdf Technical Sheet

Ordering Information

CarboProbe DS, 100 mm (3.9"), R, 3/4" connection Buy Online
CarboProbe DS, 200 mm (7.9"), R, 3/4" connection Buy Online
CarboProbe DS, 300 mm (11.8"), R, 3/4" connection Buy Online
CarboProbe DS, 400 mm (15.7"), R, 3/4" connection Buy Online
CarboProbe DS, 500 mm (19.7"), R, 3/4" connection Buy Online
CarboProbe DS, 600 mm (23.6"), R, 3/4" connection Buy Online
CarboProbe DS, 700 mm (27.5"), R, 3/4" connection Buy Online
CarboProbe DS, 800 mm (31.5"), R, 3/4" connection Buy Online
CarboProbe DS, 900 mm (35.4"), R, 3/4" connection Buy Online
CarboProbe DS, 1000 mm (39.4"), R, 3/4" connection Buy Online
CarboProbe DS, 1100 mm (43.3"), R, 3/4" connection Buy Online
CarboProbe DS, 100 mm (3.9"), S, 3/4" connection Buy Online
CarboProbe DS, 200 mm (7.9"), S, 3/4" connection Buy Online
CarboProbe DS, 300 mm (11.8"), S, 3/4" connection Buy Online
CarboProbe DS, 400 mm (15.7"), S, 3/4" connection Buy Online
CarboProbe DS, 500 mm (19.7"), S, 3/4" connection Buy Online
CarboProbe DS, 600 mm (23.6"), S, 3/4" connection Buy Online
CarboProbe DS, 700 mm (27.5"), S, 3/4" connection Buy Online
CarboProbe DS, 800 mm (31.5"), S, 3/4" connection Buy Online
CarboProbe DS, 900 mm (35.4"), S, 3/4" connection Buy Online
CarboProbe DS, 1000 mm (39.4"), S, 3/4" connection Buy Online
CarboProbe DS, 1100 mm (43.3"), S, 3/4" connection Buy Online

Do you have a special request? Don’t hesitate to ask!

Technical Characteristics

Output 0 to 1200 mv
Redout impedance This probe should be used with controlling, recording, and indicating instruments having input impedance of 8 megaohms or higher.
Accuracy ±2 mV in normal operating range
Response time Less than 1 second
Thermocouple R, S
Operating temperature From 600°C (1100°F) to 1700°C (3100°F)
Mechanical shock Resists mild mechanical shock. Handle carefully.
Available lengths 100mm (3.9"), 200mm (7.9"), 300mm (11.8"), 400mm (15.7"), 500mm (19.7"), 600mm (23.6"), 700mm (27.5"), 800mm (31.5"), 900mm (35.4"), 1000mm (39.4"), 1100mm (43.3")
Reference air Uncontaminated dry air at maximum rate of 1 l/h
External diameter 8.5 mm (~0.33")